Violation Detail
Standard Cited: 19100219 E01 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 1415848.015
Citation: 01002
Citation Type: Serious
Abatement Date: 01/29/2020
Initial Penalty: $7,293.00
Current Penalty: $0.00
Issuance Date: 01/14/2020
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0627100
Contest Date: 02/12/2020
Final Order: 10/26/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 10/26/2020 | $0.00 | 01/29/2020 | Serious | |
Penalty | C: Contested | 02/21/2020 | $7,293.00 | 01/29/2020 | Serious | |
Penalty | Z: Issued | 01/14/2020 | $7,293.00 | 01/29/2020 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): On or about July 16, 2019, at the Foundry Grind Area, the horizontal belt on the Tabor circle grinder was not fully enclosed.