Violation Detail
Standard Cited: 19260451 F15 I General requirements.
Inspection Nr: 1413216.015
Citation: 01003
Citation Type: Serious
Abatement Date: 09/27/2019 2
Initial Penalty: $13,260.00
Current Penalty: $9,282.00
Issuance Date: 09/09/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0522300
Contest Date:
Final Order: 10/01/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/01/2019 | $9,282.00 | 09/27/2019 | Serious | |
Penalty | Z: Issued | 09/09/2019 | $13,260.00 | 09/27/2019 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1926.451(f)(15)(i): A ladder placed against a structure which was not part of the scaffold was not secured against the sideways thrust exerted by the ladder: On or about April 22, 2019, the employer failed to ensure that a 6 foot Davidson Pro Series portable ladder placed on a Werner 6 foot mobile scaffold and against an entryway overhang to an apartment building was secured against the sideways thrust exerted by the ladder.