Violation Detail
Standard Cited: 19261053 B05 I Ladders.
Inspection Nr: 1407995.015
Citation: 02002B
Citation Type: Other
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/01/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity:
Report ID: 0419700
Contest Date: 07/25/2019
Final Order: 02/14/2022
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/14/2022 | $0.00 | Other | ||
Penalty | C: Contested | 07/30/2019 | $0.00 | Other | ||
Penalty | Z: Issued | 07/01/2019 | $0.00 | Other |
Text For Citation: 02 Item/Group: 002B Hazard:
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladder(s) were not used at an angle such that the horizontal distance from the top support to the foot of the ladder was approximately one-quarter of the working length of the ladder: a. On or about June 12, 2019, above the side door entrance, the roof access ladder was placed at 63-degrees, 12-degrees shallower than required by the standard.