Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1407005.015
Citation: 02014A
Citation Type: Serious
Abatement Date: 12/19/2019 2
Initial Penalty: $5,834.00
Current Penalty: $3,500.40
Issuance Date: 10/31/2019
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0112000
Contest Date: 11/27/2019
Final Order: 03/27/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/27/2020 | $3,500.40 | 12/19/2019 | Serious | |
Penalty | F: Formal Settlement | 03/27/2020 | $3,500.40 | 12/19/2019 | Serious | |
Penalty | C: Contested | 12/05/2019 | $5,834.00 | 12/19/2019 | Serious | |
Penalty | Z: Issued | 10/31/2019 | $5,834.00 | 12/19/2019 | Serious |
Text For Citation: 02 Item/Group: 014A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Block Plant, Mixer: On, or about, June 7, 2019, the spoked drive pulley provided on the mixer was partially guarded. The existing guard allow entry to the spoked area of the pulley during operation.