Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1407005.015
Citation: 02011A
Citation Type: Serious
Abatement Date: 12/19/2019 2
Initial Penalty: $10,210.00
Current Penalty: $6,126.00
Issuance Date: 10/31/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0112000
Contest Date: 11/27/2019
Final Order: 03/27/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/27/2020 | $6,126.00 | 12/19/2019 | Serious | |
Penalty | F: Formal Settlement | 03/27/2020 | $6,126.00 | 12/19/2019 | Serious | |
Penalty | C: Contested | 12/05/2019 | $10,210.00 | 12/19/2019 | Serious | |
Penalty | Z: Issued | 10/31/2019 | $10,210.00 | 12/19/2019 | Serious |
Text For Citation: 02 Item/Group: 011A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Truck Pit: On, or about, June 7, 2019, an employee was fatally injured when he was pulled into the tail pulley of an inclined conveyor belt. At the time of the incident, the conveyor system was not locked out in accordance with the employer's Lockout/Tagout procedures.