Violation Detail
Standard Cited: 19100146 C01 Permit-required confined spaces
This violation item has been deleted.
Inspection Nr: 1407005.015
Citation: 02010A
Citation Type: Serious
Abatement Date: 12/19/2019
Initial Penalty: $7,293.00
Current Penalty: $0.00
Issuance Date: 10/31/2019
Nr Instances: 4
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0112000
Contest Date: 11/27/2019
Final Order: 03/27/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/27/2020 | $0.00 | 12/19/2019 | Serious | |
Penalty | F: Formal Settlement | 03/27/2020 | $0.00 | 12/19/2019 | Serious | |
Penalty | C: Contested | 12/05/2019 | $7,293.00 | 12/19/2019 | Serious | |
Penalty | Z: Issued | 10/31/2019 | $7,293.00 | 12/19/2019 | Serious |
Text For Citation: 02 Item/Group: 010A Hazard:
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: Company: On, or about, June 18, 2019, the company had not performed an evaluation of the worksite to determine the presence of permit required confined spaces. The following spaces should have been classified as permit required confined spaces: A. Block Plant: Skip hoist pit. B. Silo 1, cement silo. C. Silo 2, white cement silo. D. The five bin compartments in the enclosed silo building.