Violation Detail
Standard Cited: 19150013 B04 Cleaning and other cold work.
This violation item has been deleted.
Inspection Nr: 1401624.015
Citation: 01001
Citation Type: Serious
Abatement Date: 12/06/2019
Initial Penalty: $13,260.00
Current Penalty: $0.00
Issuance Date: 11/13/2019
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 10
Report ID: 0626000
Contest Date: 12/05/2019
Final Order: 02/17/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 02/17/2021 | $0.00 | 12/06/2019 | Serious | |
Penalty | C: Contested | 12/06/2019 | $13,260.00 | 12/06/2019 | Serious | |
Penalty | Z: Issued | 11/13/2019 | $13,260.00 | 12/06/2019 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1915.13(b)(4): Testing was not conducted by the competent person as often as necessary during cleaning or cold work to assure that air concentrations were below 10 percent of the lower explosive limit and within the Permissible Exposure Limit (PEL) and below Immediately Dangerous to Life and Health (IDLH) levels. NOTE: Factors such as, but not limited to, temperature, volatility of the residues and other existing conditions in and about the spaces shall be considered in determining the frequency of testing necessary to assure a safe atmosphere: In the Barge DBL134, cargo tank #2, starboard side, on May 14, 2019, adequate testing was not conducted to verify the absence of flammable atmosphere in the heating coils prior to work activity.