Violation Detail
Standard Cited: 19100147 C06 II The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1395165.015
Citation: 01002
Citation Type: Serious
Abatement Date: 06/28/2019 2
Initial Penalty: $7,577.00
Current Penalty: $0.00
Issuance Date: 05/31/2019
Nr Instances: 1
Nr Exposed: 16
Related Event Code (REC):
Gravity: 5
Report ID: 0636900
Contest Date:
Final Order: 06/21/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 06/21/2019 | $0.00 | 06/28/2019 | Serious | |
Penalty | Z: Issued | 05/31/2019 | $7,577.00 | 06/28/2019 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(ii): The employer shall certify that the periodic inspections have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection. On or about May 18, 2019 and at times prior thereto, the employer did not ensure the certification identified that periodic inspections were performed by each authorized employee as required by 1910.147(c)(6)(I)(C) and (D) exposing them to being caught-in, struck-by and amputation hazards.