Violation Detail
Standard Cited: 19100178 H02 Powered industrial trucks.
Inspection Nr: 1393384.015
Citation: 02003
Citation Type: Willful
Abatement Date: 10/22/2019 2
Initial Penalty: $62,537.00
Current Penalty: $31,269.00
Issuance Date: 09/27/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity: 1
Report ID: 0213900
Contest Date: 10/23/2019
Final Order: 09/11/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 09/11/2020 | $31,269.00 | 10/22/2019 | Willful | |
Penalty | C: Contested | 10/23/2019 | $62,537.00 | 10/22/2019 | Willful | |
Penalty | Z: Issued | 09/27/2019 | $62,537.00 | 10/22/2019 | Willful |
Text For Citation: 02 Item/Group: 003 Hazard:
29 CFR 1910.178(h)(2): Where general lighting was less than 2 lumens per square foot, auxiliary directional lighting was not provided on the truck. a)Aruvil International, Inc.; Warehouse: The general lighting in the warehouse where employees used powered industrial trucks, including but not limited to the Crown SP 3000, and Raymond EASi-OPC30TT, is less than 1 lumen per square foot and the trucks did not have directional lighting, on or about 5/2/19. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.