Violation Detail
Standard Cited: 19260652 A01 Requirements for protective systems.
Inspection Nr: 1392006.015
Citation: 01005
Citation Type: Serious
Abatement Date: 08/22/2019 4
Initial Penalty: $3,978.00
Current Penalty: $2,500.00
Issuance Date: 07/29/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 1032500
Contest Date:
Final Order: 08/22/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/22/2019 | $2,500.00 | 08/22/2019 | Serious | |
Penalty | Z: Issued | 07/29/2019 | $3,978.00 | 08/22/2019 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with paragraph (b) or (c) of this section: a) On April 10, 2019, and at times prior thereto, employees were working in a trench that was approximately 4.0 - 8.0 feet in depth. Abatement certification and documentation ARE required for this item.