Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
Inspection Nr: 1386717.015
Citation: 01003
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $10,210.00
Current Penalty: $7,147.00
Issuance Date: 06/03/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC): A
Gravity: 10
Report ID: 0627100
Contest Date: 06/24/2019
Final Order: 06/08/2020
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 06/08/2020 | $7,147.00 | Serious | ||
Penalty | C: Contested | 06/25/2019 | $10,210.00 | Serious | ||
Penalty | Z: Issued | 06/03/2019 | $10,210.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about March 22, 2019 and at times prior thereto, employees were exposed to an unguarded rotating shaft in the vicinity of the filter house. This condition exposed employees to caught in hazards.