Violation Detail
Standard Cited: 19100106 H08 III Flammable liquids.
Inspection Nr: 1386232.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $7,956.00
Current Penalty: $4,773.60
Issuance Date: 05/09/2019
Nr Instances: 1
Nr Exposed: 8
Related Event Code (REC):
Gravity: 5
Report ID: 0418800
Contest Date:
Final Order: 05/20/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/20/2019 | $4,773.60 | Serious | ||
Penalty | Z: Issued | 05/09/2019 | $7,956.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.106(h)(8)(iii): Combustible waste material and residues in a building or operating area shall be kept to a minimum, stored in closed metal waste cans, and disposed of daily: On or about March 19, 2019, at the jobsite location 591 SW 13th Terrace Pompano Beach, FL 33069 assembly department, the rags used for the brake cleaner (Category 2 flammable) were dispensed into an opened bag, exposing employees to a fire hazard. -