Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1382880.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 08/26/2019 2
Initial Penalty: $10,419.00
Current Penalty: $10,419.00
Issuance Date: 08/12/2019
Nr Instances: 2
Nr Exposed: 3
Related Event Code (REC):
Gravity: 5
Report ID: 0523900
Contest Date: 09/05/2019
Final Order: 09/27/2021
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/27/2021 | $10,419.00 | 08/26/2019 | Serious | |
Penalty | C: Contested | 09/09/2019 | $10,419.00 | 08/26/2019 | Serious | |
Penalty | Z: Issued | 08/12/2019 | $10,419.00 | 08/26/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: (a) Vemag dough extruder model HP15E; The machine specific energy control (lockout) procedures did not identify how to shut down, isolate, and secure pneumatic energy. (b) Stork Texwrap package wrapper S/N S3081; The machine specific energy control (lockout) procedure did not identify how to shut down, isolate, and secure thermal energy.