Violation Detail
Standard Cited: 19100219 E02 I Mechanical power-transmission apparatus.
Inspection Nr: 1380173.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 08/09/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 08/01/2019
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC):
Gravity: 5
Report ID: 0419400
Contest Date:
Final Order: 09/03/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/03/2019 | $0.00 | 08/09/2019 | Serious | |
Penalty | Z: Issued | 08/01/2019 | $0.00 | 08/09/2019 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.219(e)(2)(i): Overhead horizontal belt(s) with lower parts seven 7 feet or less from the floor(s) or platform(s) were not guarded on the sides and bottom in accordance with the requirements specified at CFR 1910.219(o)(3)(a): (a) Bin Loading/Unloading Area - On or about February 14, 2019 the fill auger had an unguarded belts with ingoing nip points, exposing employees to caught-in hazards.