Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
This violation item has been deleted.
Inspection Nr: 1378263.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 04/23/2019
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 03/07/2019
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 03/25/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 03/25/2019 | $0.00 | 04/23/2019 | Serious | |
Penalty | Z: Issued | 03/07/2019 | $0.00 | 04/23/2019 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. On 2/11/19, at the Athens facility, the employer did not ensure the periodic inspection corrected deficiencies found in the specific written procedures. On Extruder 9 Die Heater Bands and Extruder 9 Extruder procedures heat energy was not listed as an energy on the specific written procedure (400-450 degrees).