Violation Detail
Standard Cited: 19100219 C03 Mechanical power-transmission apparatus.
Inspection Nr: 1375672.015
Citation: 01009A
Citation Type: Serious
Abatement Date: 07/25/2019 2
Initial Penalty: $4,508.00
Current Penalty: $2,254.00
Issuance Date: 06/07/2019
Nr Instances: 4
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 07/09/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/09/2019 | $2,254.00 | 07/25/2019 | Serious | |
Penalty | Z: Issued | 06/07/2019 | $4,508.00 | 07/25/2019 | Serious |
Text For Citation: 01 Item/Group: 009A Hazard:
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing(s): Building 6: On, or about, April 16, 2019, vertical capstan shafts located under plating enclosures were not provided with guards: A. Line 26, Tank 10, Nickel tank. B. Line 26, Tin tank. C. Line 19, Rinse Tank. D. Line 19 Nickel Tank.