Violation Detail
Standard Cited: 19100147 D The control of hazardous energy (lockout/tagout).
Inspection Nr: 1373959.015
Citation: 01002
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $9,282.00
Current Penalty: $6,497.00
Issuance Date: 05/07/2019
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC): R
Gravity: 10
Report ID: 0524500
Contest Date:
Final Order: 05/22/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/22/2019 | $6,497.00 | Serious | ||
Penalty | Z: Issued | 05/07/2019 | $9,282.00 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about January 16, 2019, employees were exposed to machine hazards associated with moving parts and thermal hazards during change-over operations on the MAAC Thermoforming Machine, Model 85R4D (in house name, Machine 7). The employer failed to implement energy control application steps as the machine was not turned off or placed into a safe mode to perform the change-over work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(I)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine hazards during the change over operations.