Violation Detail
Standard Cited: 19100219 C04 I Mechanical power-transmission apparatus.
Inspection Nr: 1369678.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $10,419.00
Current Penalty: $0.00
Issuance Date: 06/26/2019
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): A
Gravity: 5
Report ID: 0111400
Contest Date: 07/19/2019
Final Order: 11/12/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/12/2019 | $0.00 | Serious | ||
Penalty | C: Contested | 10/29/2019 | $10,419.00 | Serious | ||
Penalty | Z: Issued | 06/26/2019 | $10,419.00 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) Separating Room: South Roto-Screen - A shaft from a sixty to 1 (60:1) gear reduction box measuring approximately one (1) inch diameter by two and three-quarter (2 3/4) inches in length with an unused keyway was not guarded exposing employees to caught-in and struck-by hazards. (a) Separating Room: North Roto-Screen - A shaft from a sixty to 1 (60:1) gear reduction box measuring approximately one (1) inch diameter by two and three-quarter (2 3/4) inches in length with an approximately quarter (1/4) inch keyway was not guarded exposing employees to caught-in and struck-by hazards.