Violation Detail
Standard Cited: 19100023 B10 Ladders.
Inspection Nr: 1351997.015
Citation: 01001A
Citation Type: Other
Abatement Date: 04/23/2019 2
Initial Penalty: $5,304.00
Current Penalty: $3,209.00
Issuance Date: 04/01/2019
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity:
Report ID: 0213900
Contest Date:
Final Order: 04/22/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 04/22/2019 | $3,209.00 | 04/23/2019 | Other | |
Penalty | Z: Issued | 04/01/2019 | $5,304.00 | 04/23/2019 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.23(b)(10): Ladders with structural or other defects were not immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with �1910.145 and removed from service until repaired in accordance with �1910.22(d), or replaced; a) Fabrication: Employees were utilizing a 2 foot Husky aluminum step ladder with bent rear legs and the front leg had metal patch holding the spreader bar in place, on or about 10/30/2018. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM, FAILURE TO DO SO WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 AS PER 29 CFR 1903.19.