Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1350167.015
Citation: 02001
Citation Type: Other
Abatement Date: 3
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/11/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity:
Report ID: 0316400
Contest Date:
Final Order: 01/07/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/07/2019 | $0.00 | Other | ||
Penalty | Z: Issued | 12/11/2018 | $0.00 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: (a) Metal Fabrication Area: October 1, 2018 and times prior, employees used energy control procedures when performing service and maintenance of machinery such as, but not limited to, the Cincinnati Shear and Roll Former, which have multiple energy sources. An annual periodic inspection of each energy control procedure and a review of each employee's responsibilities under the energy control procedure was not performed.