Violation Detail
Standard Cited: 19100212 A03 II General requirements for all machines.
Inspection Nr: 1341398.015
Citation: 01003
Citation Type: Serious
Abatement Date: 11/21/2018 2
Initial Penalty: $9,054.00
Current Penalty: $5,478.00
Issuance Date: 11/15/2018
Nr Instances: 5
Nr Exposed: 5
Related Event Code (REC): R
Gravity: 10
Report ID: 0521700
Contest Date:
Final Order: 12/13/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/13/2018 | $5,478.00 | 11/21/2018 | Serious | |
Penalty | Z: Issued | 11/15/2018 | $9,054.00 | 11/21/2018 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle: a. On or about August 14, 2018, employees were operating the Chicago Press Brake machine and the point of operation guard was not designed and constructed in such a manner to prevent any part of employees body from being in the danger zone during operation, thereby exposing employees to amputation hazards.