Violation Detail
Standard Cited: 19100219 E03 I Mechanical power-transmission apparatus.
Inspection Nr: 1337312.015
Citation: 01007C
Citation Type: Serious
Abatement Date: 12/18/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/06/2018
Nr Instances: 2
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0418800
Contest Date:
Final Order: 12/26/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/26/2018 | $0.00 | 12/18/2018 | Serious | |
Penalty | Z: Issued | 12/06/2018 | $0.00 | 12/18/2018 | Serious |
Text For Citation: 01 Item/Group: 007C Hazard:
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts shall be enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section: a. On or about August 24, 2018, at the Bindery Department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A guard covering a belt and pulley assembly on a guillotine cutter (i.e. Polar, Model 76EM, Serial Number 5261234) was made out of cardboard and secured with Velcro, exposing employees to caught by hazard. b. On or about August 24, 2018, at the Bindery Department of Nupress of Miami Inc., 2050 NW 94th Ave, Doral, FL. A guard covering a belt and pulley assembly on a guillotine cutter (i.e. EMC-Monitor, Model 115MON, Serial Number 5531563)was made out of cardboard and secured with Velcro, exposing employees to caught by hazard.