Violation Detail
Standard Cited: 19100134 F02 Respiratory Protection.
Inspection Nr: 1336547.015
Citation: 01003C
Citation Type: Serious
Abatement Date: 01/22/2019 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 12/03/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0112000
Contest Date:
Final Order: 12/28/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 12/28/2018 | $0.00 | 01/22/2019 | Serious | |
Penalty | Z: Issued | 12/03/2018 | $0.00 | 01/22/2019 | Serious |
Text For Citation: 01 Item/Group: 003C Hazard:
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: Recycling Center, picker's platform; On or about 8/16/18, the employer did not provide an annual fit test to an employee required to wear a tight-fitting MSA half-face air-purifying respirator with P100 filters.