Violation Detail
Standard Cited: 19100217 C01 I Mechanical power presses.
Inspection Nr: 1334912.015
Citation: 01006
Citation Type: Serious
Abatement Date: 03/15/2019 2
Initial Penalty: $9,282.00
Current Penalty: $5,600.00
Issuance Date: 01/25/2019
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC):
Gravity: 10
Report ID: 0134000
Contest Date: 02/19/2019
Final Order: 04/22/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/22/2019 | $5,600.00 | 03/15/2019 | Serious | |
Penalty | C: Contested | 02/28/2019 | $9,282.00 | 03/01/2019 | Serious | |
Penalty | Z: Issued | 01/25/2019 | $9,282.00 | 03/01/2019 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es) 125 Gloucester Ave, Gloucester, MA; Press shop Employees operating mechanical power presses did not have point of operation guards, or properly applied point of operation devices on presses used in the press shop, including, but not limited to; a) On or about July 28, 2018, Bliss mechanical power press shop ID 14108 was operated by a foot pedal without a point of operation guard. An employee suffered a fingertip amputation. b) On or about August 31, 2018, Torc-Pac mechanical power press shop ID 14107 was operated without a point of operation guard. Abatement documentation is required for this item in accordance with the requirements of 29 CFR 1903.19(d)