Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1328019.015
Citation: 01001
Citation Type: Serious
Abatement Date: 10/09/2018 2
Initial Penalty: $12,934.00
Current Penalty: $7,760.40
Issuance Date: 09/12/2018
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0626300
Contest Date:
Final Order: 10/02/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/02/2018 | $7,760.40 | 10/09/2018 | Serious | |
Penalty | Z: Issued | 09/12/2018 | $12,934.00 | 10/09/2018 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source: a) This violation occurred on or about June 28, 2018; where at least one (1) employee who was performing maintenance on the Ploog Compactor (Proctor) machine (m/n M100-202021359, s/n 100-207122540) were exposed to caught-in hazards.