Violation Detail
Standard Cited: 19100212 A01 General requirements for all machines.
Inspection Nr: 1319033.015
Citation: 01003
Citation Type: Serious
Abatement Date: 12/28/2018 2
Initial Penalty: $12,934.00
Current Penalty: $12,000.00
Issuance Date: 09/25/2018
Nr Instances: 5
Nr Exposed: 9
Related Event Code (REC):
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 10/22/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/22/2018 | $12,000.00 | 12/28/2018 | Serious | |
Penalty | Z: Issued | 09/25/2018 | $12,934.00 | 10/22/2018 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a. On or about May 14, 2018, employees were exposed to caught-by hazards when walking and working near the F&K printing press in that rollers (print cylinders) on lacquer end of F&K printing press (1 set) were not adequately guarded. b. On or about May 14, 2018, employees were exposed to caught by hazards when walking and working near the F&K printing press in that rollers (print cylinders) on ink end of F&K printing press (3 sets) were not adequately guarded. c. On or about May 14, 2018, employees were exposed to caught by hazards when the belts feeding the shaker tables were not guarded to prevent employees from being caught by the belt ingoing nip points d. On or about May 14, 2018, employees were exposed to caught by hazards when the belts on the shaker tables were not guarded to prevent employees from being caught by the belt ingoing nip points e. On or about May 14, 2018, employees were exposed to caught by hazards when the gate/door on the shaker table returned to the closed position while the machine was running and the ingoing nip points were not guarded In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.