Violation Detail
Standard Cited: 19100147 C04 II The control of hazardous energy (lockout/tagout).
Inspection Nr: 1318500.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 12/10/2018 2
Initial Penalty: $12,806.00
Current Penalty: $6,852.00
Issuance Date: 10/22/2018
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): C
Gravity: 10
Report ID: 0418400
Contest Date: 11/14/2018
Final Order: 09/25/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/25/2019 | $6,852.00 | 12/10/2018 | Serious | |
Penalty | C: Contested | 11/20/2018 | $12,806.00 | 12/10/2018 | Serious | |
Penalty | Z: Issued | 10/22/2018 | $12,806.00 | 12/10/2018 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Throughout Facility - On or about May 23, 2018 and at times prior to, the employer did not develop, document or implement specific procedures to control hazardous energy when performing maintenance and service activities on equipment such as but not limited to hot saws, conveyor belts, press furnaces, aging ovens, and billet shears, thus exposing employees to caught-in, struck-by, crushed-by, and fall hazards.