Violation Detail
Standard Cited: 19100134 F01 Respiratory Protection.
This violation item has been deleted.
Inspection Nr: 1315660.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 12/03/2018
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/30/2018
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 5
Report ID: 0112600
Contest Date: 11/07/2018
Final Order: 11/29/2019
Emphasis:
Substance: 9000
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 11/29/2019 | $0.00 | 12/03/2018 | Serious | |
Penalty | C: Contested | 11/15/2018 | $0.00 | 12/03/2018 | Serious | |
Penalty | Z: Issued | 10/30/2018 | $0.00 | 12/03/2018 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting face piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT): (Construction reference 1926.103): One MGM Way, Springfield MA: On or about 5/11/18, employees were required to wear filtering facepiece respirators while cutting glass fiber reinforced concrete (GFRC) with handheld power saws, and the employer did not ensure that they had passed the appropriate qualitative or quantitative fit test.