Violation Detail
Standard Cited: 19100147 C07 III B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1298602.015
Citation: 01003D
Citation Type: Serious
Abatement Date: 09/10/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/29/2018
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date:
Final Order: 07/24/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/24/2018 | $0.00 | 09/10/2018 | Serious | |
Penalty | Z: Issued | 06/29/2018 | $0.00 | 08/06/2018 | Serious |
Text For Citation: 01 Item/Group: 003D Hazard:
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not provided whenever a periodic inspection under 29 CFR 1910.147(c)(6) revealed that there were deviations from or inadequacies in the employee's knowledge or use of the energy control procedures: a) Throughout the facility, on or about 2/28/18: Maintenance supervisor was not retrained on the purpose and function of energy control procedures and on the requirement to perform periodic (at least annual) inspections of the energy control procedures for equipment with multiple energy sources including, but not limited to electric kilns with electrical and thermal energy; and presses with electrical, hydraulic and pneumatic energy. Abatement certification must be submitted for this item.