Violation Detail
Standard Cited: 19100147 D03 The control of hazardous energy (lockout/tagout).
Inspection Nr: 1282066.015
Citation: 01003
Citation Type: Other
Abatement Date: 3
Initial Penalty: $9,054.00
Current Penalty: $10,000.00
Issuance Date: 04/20/2018
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC): R
Gravity:
Report ID: 0626000
Contest Date:
Final Order: 05/21/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 05/21/2018 | $10,000.00 | Other | ||
Penalty | Z: Issued | 04/20/2018 | $9,054.00 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): At the Nacelle, employees conducted maintenance services to wind turbine blades, an inadequate locking device system was used at the high speed shaft to isolate the equipment.