Violation Detail
Standard Cited: 19100179 J02 III Overhead and gantry cranes.
Inspection Nr: 1269082.015
Citation: 01003B
Citation Type: Serious
Abatement Date: 12/01/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/23/2017
Nr Instances: 1
Nr Exposed: 23
Related Event Code (REC): C
Gravity: 5
Report ID: 0522300
Contest Date:
Final Order: 10/30/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/30/2017 | $0.00 | 12/01/2017 | Serious | |
Penalty | Z: Issued | 10/23/2017 | $0.00 | 10/31/2017 | Serious |
Text For Citation: 01 Item/Group: 003B Hazard:
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed: On or about October 10, 2017, the employer did not ensure that hook inspections were performed and documented as required. Safety latches; affixed to the hooks/hoisting apparatus of the overhead crane located above the plasma table, were not operational. Employees performing crane operations are not protected from potential hazards created by accidental load disengagement.