Violation Detail
Standard Cited: 19100147 C07 III A The control of hazardous energy (lockout/tagout).
Inspection Nr: 1249487.015
Citation: 01005
Citation Type: Other
Abatement Date: 02/08/2018 2
Initial Penalty: $12,934.00
Current Penalty: $8,000.00
Issuance Date: 01/22/2018
Nr Instances: 1
Nr Exposed: 3
Related Event Code (REC):
Gravity:
Report ID: 0213400
Contest Date: 02/09/2018
Final Order: 03/04/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/04/2019 | $8,000.00 | 02/08/2018 | Other | |
Penalty | C: Contested | 02/15/2018 | $12,934.00 | 02/08/2018 | Serious | |
Penalty | Z: Issued | 01/22/2018 | $12,934.00 | 02/08/2018 | Serious |
Text For Citation: 01 Item/Group: 005 Hazard:
29 CFR 1910.147(c)(7)(iii)(A): Retraining was not provided for authorized and affected employees when there was a change in their job assignments, a change in machines, equipment or processes that presented a new hazard, or when there was a change in the energy control procedures: a. 190 Strykers Rd., Phillipsburg, NJ - Deco Department The employer did not provide retraining for authorized employees performing maintenance and repairs on Decorating machine S-02, OMSO, NOVAX M UV, Serial # 130141194 after it was installed in the Phillipsburg plant with new power sources and locations for lockout devices. Violation occurred on or about July 25, 2017