Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1248291.015
Citation: 02001
Citation Type: Other
Abatement Date: 02/02/2018 2
Initial Penalty: $1,141.00
Current Penalty: $11,500.00
Issuance Date: 01/08/2018
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity:
Report ID: 0524200
Contest Date: 02/07/2018
Final Order: 04/22/2019
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 04/22/2019 | $11,500.00 | 02/02/2018 | Other | |
Penalty | C: Contested | 02/21/2018 | $1,141.00 | 02/02/2018 | Other | |
Penalty | Z: Issued | 01/08/2018 | $1,141.00 | 02/02/2018 | Other |
Text For Citation: 02 Item/Group: 001 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Bay 8- On July 19, 2017, the employer failed to conduct periodic inspections of each energy control procedure at least annually to verify the procedures were adequate and were being applied properly. This would include an inspection of the machine specific procedures for the Tsune Circular Sawing Machines and Amada Horizontal Bandsaws. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).