Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1240078.015
Citation: 01003
Citation Type: Serious
Abatement Date: 09/07/2017 2
Initial Penalty: $12,548.00
Current Penalty: $8,783.60
Issuance Date: 07/21/2017
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity: 10
Report ID: 0418100
Contest Date:
Final Order: 08/09/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 08/09/2017 | $8,783.60 | 09/07/2017 | Serious | |
Penalty | Z: Issued | 07/21/2017 | $12,548.00 | 09/07/2017 | Serious |
Text For Citation: 01 Item/Group: 003 Hazard:
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed. On 6/15/17, at the Winder facility, the employer had not conducted a periodic inspection of lockout procedures on an, at least, annual basis and not all equipment had a specific written procedure and the documented procedures did not account for all energies on machines.