Violation Detail
Standard Cited: 19100179 J02 IV Overhead and gantry cranes.
Inspection Nr: 1227257.015
Citation: 01001B
Citation Type: Serious
Abatement Date: 10/26/2017 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/05/2017
Nr Instances: 5
Nr Exposed: 10
Related Event Code (REC): C
Gravity: 10
Report ID: 0627510
Contest Date:
Final Order: 10/27/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/27/2017 | $0.00 | 10/26/2017 | Serious | |
Penalty | Z: Issued | 10/05/2017 | $0.00 | 10/26/2017 | Serious |
Text For Citation: 01 Item/Group: 001B Hazard:
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed: Employer did not conduct monthly chain inspections with a certification records for overhead hoists exposing employees to struck-by hazards. Equipment includes but is not limited to the following: a) JIB MFG: ACG overhead crane JIB Serial # H058 with Harrington hoist model NER005L, Serial # 62021 located at W/C 82 Manual Grinder. b) JIB MFG: Gorbel overhead crane JIB Serial # AL E35-793 with Harrington hoist model NER005L, located at W/C 825 Manual Lathes. c) MFG Anchor Crane & Hoist overhead crane JIB Serial # 206290 with CM hoist model Loadstar, serial #: L0842QX located at W/C 15 SF-SP d) JIB MFG: Gorbel overhead crane JIB Serial # A70727 with Harrington hoist model NER005L, Serial # 65350 located at W/C 53. e) JIB MFG Anchor Crane & Hoist and JIB Serial # 104510 with Budgit hoist model 11584835, hoist serial # 247390 located at the Furnace Room.