Violation Detail
Standard Cited: 19101026 E02
Inspection Nr: 1222353.015
Citation: 01004
Citation Type: Serious
Abatement Date: 11/17/2017 2
Initial Penalty: $8,873.00
Current Penalty: $5,000.00
Issuance Date: 10/04/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 10
Report ID: 0214200
Contest Date:
Final Order: 10/26/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/26/2017 | $5,000.00 | 11/17/2017 | Serious | |
Penalty | Z: Issued | 10/04/2017 | $8,873.00 | 11/17/2017 | Serious |
Text For Citation: 01 Item/Group: 004 Hazard:
29 CFR 1910.1026(e)(2): The employer did not ensure that a regulated area for chromium (VI) was demarcated from the rest of the workplace in a manner that adequately established and alerted employees of the boundaries of the regulated area: a) Weld shop There was no indication that certain welding areas involved operations which liberated hexavalent chromium. A welder performing TIG and MIG (flux core) welding on a stainless steel hopper was exposed to 13.7 micrograms hexavalent chromium per cubic meter of air, as an 8 hour time weighted average, which was 2.7 times the permissible exposure limit of 5 micrograms per cubic meter. Sampling was conducted for 407 minutes, with zero exposure assumed for 73 minutes not sampled. Violation occurred on or about 5/1/17.