Violation Detail
Standard Cited: 19100147 C04 II B The control of hazardous energy (lockout/tagout).
Inspection Nr: 1222136.015
Citation: 01002A
Citation Type: Serious
Abatement Date: 12/07/2017 2
Initial Penalty: $9,054.00
Current Penalty: $2,580.35
Issuance Date: 09/06/2017
Nr Instances: 1
Nr Exposed: 6
Related Event Code (REC):
Gravity: 5
Report ID: 0420600
Contest Date:
Final Order: 10/05/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 10/05/2017 | $2,580.35 | 12/07/2017 | Serious | |
Penalty | Z: Issued | 09/06/2017 | $9,054.00 | 12/07/2017 | Serious |
Text For Citation: 01 Item/Group: 002A Hazard:
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy. a. At the establishment press area. Lockout procedures for equipment such as, but not limited to, the Gammerler STC-70 Stacker, were not written with clear and specific procedures for shut down, on or about, 03/21/2017.