Violation Detail
Standard Cited: 19100107 G02 Spray finishing using flammable and combustible materials.
Inspection Nr: 1219419.015
Citation: 01002G
Citation Type: Other
Abatement Date: 03/19/2018 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 07/28/2017
Nr Instances: 1
Nr Exposed: 10
Related Event Code (REC):
Gravity:
Report ID: 0523400
Contest Date: 08/22/2017
Final Order: 01/18/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/18/2018 | $0.00 | 03/19/2018 | Other | |
Penalty | C: Contested | 08/30/2017 | $0.00 | 08/09/2017 | Serious | |
Penalty | Z: Issued | 07/28/2017 | $0.00 | 08/09/2017 | Serious |
Text For Citation: 01 Item/Group: 002G Hazard:
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary: (a) In the paint booth there was an excessive build-up of paint in the area where the filters were missing below the conveyor.