Violation Detail
Standard Cited: 19100179 J02 Overhead and gantry cranes.
This violation item has been deleted.
Inspection Nr: 1218089.015
Citation: 01001
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $4,155.00
Current Penalty: $0.00
Issuance Date: 09/01/2017
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity: 1
Report ID: 0523400
Contest Date:
Final Order: 09/26/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 09/26/2017 | $0.00 | Serious | ||
Penalty | Z: Issued | 09/01/2017 | $4,155.00 | Serious |
Text For Citation: 01 Item/Group: 001 Hazard:
29 CFR 1910.179(j)(2): The following items were not inspected for defects at intervals as defined in paragraph (j)(1)(ii) of this section or as specifically indicated, including observation during operation for any defects which might appear between regular inspections: (a) West Building - Jib crane #2144: Periodic inspection of 2000 pound capacity beam cantilever jib crane did not identify the ability of the crane to automatically swing a load on it's own from an at rest position. This automatic tendency to self start to swing a load puts employees at risk of a struck by hazard. (b) West Building - Jib crane #2064: Periodic inspection of 2000 pound capacity beam cantilever jib crane did not identify the ability of the crane to automatically swing a load on it's own from an at rest position. This automatic tendency to self start to swing a load puts employees at risk of a struck by hazard.