Violation Detail
Standard Cited: 19100219 D01 Mechanical power-transmission apparatus.
Inspection Nr: 1197726.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 3
Initial Penalty: $9,959.00
Current Penalty: $9,959.00
Issuance Date: 05/19/2017
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC): C
Gravity: 5
Report ID: 0521700
Contest Date: 06/05/2017
Final Order: 09/20/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 09/20/2018 | $9,959.00 | Serious | ||
Penalty | C: Contested | 08/22/2017 | $9,959.00 | Serious | ||
Penalty | Z: Issued | 05/19/2017 | $9,959.00 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) On or about March 13, 2017, at the above located workplace, label machine operators and maintenance employees were required to work with a labeler machine which had a unguarded belt and pulley approximately 2 feet above the floor. The employees were exposed to the hazards associated with the moving and rotating equipment.