Violation Detail
Standard Cited: 19100147 C04 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1177547.015
Citation: 01001A
Citation Type: Serious
Abatement Date: 12/22/2016 2
Initial Penalty: $12,471.00
Current Penalty: $12,471.00
Issuance Date: 11/28/2016
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC): R
Gravity: 10
Report ID: 0418300
Contest Date:
Final Order: 12/28/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 11/28/2016 | $12,471.00 | 12/22/2016 | Serious |
Text For Citation: 01 Item/Group: 001A Hazard:
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) On or about 09/01/2016 - Dato department, building #3, employees performing maintenance and servicing on machinery such as, but not limited to, the Selco WNT 600 panel saw with electrical and pneumatic sources of energy were not utilizing the established specific lockout and tagout procedure to isolate the energy sources.