Violation Detail
Standard Cited: 19260251 E08 Rigging equipment for material handling.
Inspection Nr: 1166164.015
Citation: 01002B
Citation Type: Serious
Abatement Date: 10/28/2016 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 10/11/2016
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0213400
Contest Date: 10/26/2016
Final Order: 10/02/2018
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 10/02/2018 | $0.00 | 10/28/2016 | Serious | |
Penalty | C: Contested | 11/01/2016 | $0.00 | 10/28/2016 | Serious | |
Penalty | Z: Issued | 10/11/2016 | $0.00 | 10/28/2016 | Serious |
Text For Citation: 01 Item/Group: 002B Hazard:
29 CFR 1926.251(e)(8): Synthetic web slings were not immediately removed from service if any of the following conditions specified in 1926.251(e)(8)(i) through (e)(8)(v) were present: (i) Acid or caustic burns; (ii) Melting or charring of any part of the sling surface; (iii) snags, punctures, tears, or cuts; (iv) broken or worn stitches; or (v) distortion of fittings. a: Harbortown Blvd, Building 43, Perth Amboy, NJ: The synthetic web sling which was being used to lift large TrussJoist Parallam PSL beams and had several visible defects and damage had not been removed from service. This hazard was observed on 7/30/16.