Violation Detail
Standard Cited: 19100212 A02 General requirements for all machines.
Inspection Nr: 1163153.015
Citation: 02016
Citation Type: Serious
Abatement Date: 01/20/2017 2
Initial Penalty: $6,236.00
Current Penalty: $3,741.00
Issuance Date: 12/22/2016
Nr Instances: 2
Nr Exposed: 2
Related Event Code (REC): C
Gravity: 5
Report ID: 0418100
Contest Date:
Final Order: 01/17/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 01/17/2017 | $3,741.00 | 01/20/2017 | Serious | |
Penalty | Z: Issued | 12/22/2016 | $6,236.00 | 01/20/2017 | Serious |
Text For Citation: 02 Item/Group: 016 Hazard:
29 CFR 1910.212(a)(2): Guard(s) on machine(s) were not affixed to the machine or secured elsewhere when attachment to the machine was not possible: On or about July 19, 2016, employees were exposed to caught-in hazards when equipment such as, but not limited to the equipment listed below did not have the guard secured. a. A bolt was missing on the expanded metal cage that guarded the wire insertion bar/blade on the horizontal baler. b. Bolts were missing on the guard covering the horizontal balers hinged cover. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).