Violation Detail
Standard Cited: 19100147 C06 I The control of hazardous energy (lockout/tagout).
Inspection Nr: 1156290.015
Citation: 01002
Citation Type: Serious
Abatement Date: 08/17/2016 2
Initial Penalty: $6,300.00
Current Penalty: $3,150.00
Issuance Date: 06/30/2016
Nr Instances: 1
Nr Exposed: 1
Related Event Code (REC):
Gravity: 10
Report ID: 0729300
Contest Date:
Final Order: 07/12/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 07/12/2016 | $3,150.00 | 08/17/2016 | Serious | |
Penalty | Z: Issued | 06/30/2016 | $6,300.00 | 08/17/2016 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.147(c)(6)(i): The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: On 06/16/2016, J. V. Manufacturing, Inc. failed to conduct an at least annual periodic inspection for the installer. The last training was dated 12/4/2014.