Violation Detail
Standard Cited: 19100023 A02 Ladders.
Inspection Nr: 1146111.015
Citation: 01002
Citation Type: Serious
Abatement Date: 07/31/2017 2
Initial Penalty: $6,236.00
Current Penalty: $4,286.00
Issuance Date: 10/27/2016
Nr Instances: 2
Nr Exposed: 4
Related Event Code (REC):
Gravity: 5
Report ID: 0215800
Contest Date: 11/10/2016
Final Order: 08/17/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 08/17/2017 | $4,286.00 | 07/31/2017 | Serious | |
Penalty | C: Contested | 11/30/2016 | $6,236.00 | 11/08/2016 | Serious | |
Penalty | Z: Issued | 10/27/2016 | $6,236.00 | 11/08/2016 | Serious |
Text For Citation: 01 Item/Group: 002 Hazard:
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening: a) On or about 5/6/2016, Mixer Area: Ladderway openings on the first and second level platforms were not provided with swing gates or offsets. Employees exposed to falls of up to 16 feet b) On or about 6/7/2016, Aggregate elevator Area: The ladderway opening at the top of the access ladder was not provided with swing gates or off sets. Employees exposed to falls of 28 feet. Abatement certification is required for these items.