Violation Detail
Standard Cited: 19100134 E01 Respiratory Protection.
Inspection Nr: 1133173.015
Citation: 01005B
Citation Type: Serious
Abatement Date: 10/19/2016 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 09/15/2016
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity: 10
Report ID: 0213400
Contest Date:
Final Order: 10/11/2016
Emphasis:
Substance: B104
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | Z: Issued | 09/15/2016 | $0.00 | 10/19/2016 | Serious |
Text For Citation: 01 Item/Group: 005B Hazard:
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or was required to use the respirator in the workplace: Exigo Metal Works/Hillside, NJ- Production Area: Employer did not provide medical evaluations for employees who were required to wear respirators in the workplace. Employees were required to wear respiratory protection such as but not limited to: a) Half face, air purifying respirators with cartridges b) N95 filtering face piece respirators Condition observed on or about March 17, 2016.