Violation Detail
Standard Cited: 19100243 A02 I Guarding of portable powered tools.
This violation item has been deleted.
Inspection Nr: 1112073.015
Citation: 01011
Citation Type: Serious
Abatement Date: 03/09/2016 2
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 02/19/2016
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 10
Report ID: 0418100
Contest Date: 03/15/2016
Final Order: 03/13/2017
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 03/13/2017 | $0.00 | 03/09/2016 | Serious | |
Penalty | C: Contested | 03/23/2016 | $7,000.00 | 03/09/2016 | Serious | |
Penalty | Z: Issued | 02/19/2016 | $7,000.00 | 03/09/2016 | Serious |
Text For Citation: 01 Item/Group: 011 Hazard:
29 CFR 1910.243(a)(2)(i): Constant pressure switch(es) or control(s) which would shut off the power when pressure is released were not provided on the Jarvis Hydraulic Powered Breaking Saw(s): On or about 12/10/15 in the boning production area at 1301 New Savannah Road, Augusta, GA: Employee(s) were observed operating the Jarvis Hydraulic Powered Breaking Saw with about an 12 inch blade to cut sections of the meat that was not equipped with fully operational constant pressure switches. On 12/3/15 an employee was sustained a laceration to his stomach while operating the Hydraulic Powered Breaking Saw during production.