Violation Detail
Standard Cited: 19100212 B General requirements for all machines.
Inspection Nr: 1111049.015
Citation: 03001
Citation Type: Other
Abatement Date: 06/14/2016 2
Initial Penalty: $0.00
Current Penalty: $0.00
Issuance Date: 06/08/2016
Nr Instances: 1
Nr Exposed: 4
Related Event Code (REC):
Gravity:
Report ID: 0213900
Contest Date: 06/29/2016
Final Order: 12/14/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | J: ALJ Decision | 12/14/2016 | $0.00 | 06/14/2016 | Other | |
Penalty | C: Contested | 06/29/2016 | $0.00 | 06/14/2016 | Other | |
Penalty | Z: Issued | 06/08/2016 | $0.00 | 06/14/2016 | Other |
Text For Citation: 03 Item/Group: 001 Hazard:
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: a) Boccella Precast LLC. - Storage area: Top heavy machinery such as the Delta drill press Model #83-122, S/N 72027-A YB was not bolted to the floor, on or about 12/15/2015.