Violation Detail
Standard Cited: 19100410 C02 Qualifications of dive team.
Inspection Nr: 1107089.015
Citation: 01001C
Citation Type: Other
Abatement Date: 3
Initial Penalty: $7,000.00
Current Penalty: $0.00
Issuance Date: 01/11/2016
Nr Instances: 1
Nr Exposed: 2
Related Event Code (REC):
Gravity:
Report ID: 0419700
Contest Date:
Final Order: 02/03/2016
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | I: Informal Settlement | 02/03/2016 | $0.00 | Other | ||
Penalty | Z: Issued | 01/11/2016 | $7,000.00 | Serious |
Text For Citation: 01 Item/Group: 001C Hazard:
29 CFR 1910.410(c)(2): The designated person-in-charge did not have experience and training in the conduct of the assigned diving operation (is applicable to the standard by 29 CFR 1926.1076 which incorporates the General Industry requirement): a. On or about October 13, 2015, at Blount Island Marine Terminal Berth 35, employees performing diving operations did not ensure the designated person-in-charge had the training and experience required to plan, perform and oversee the dive operations in a safe manner.