Violation Detail
Standard Cited: 19100219 C02 I Mechanical power-transmission apparatus.
This violation item has been deleted.
Inspection Nr: 109779.015
Citation: 01006
Citation Type: Serious
Abatement Date: 03/27/2012
Initial Penalty: $5,000.00
Current Penalty: $0.00
Issuance Date: 03/22/2012
Nr Instances: 1
Nr Exposed: 5
Related Event Code (REC):
Gravity: 5
Report ID: 0830600
Contest Date: 04/12/2012
Final Order: 01/09/2013
Emphasis:
Type | Latest Event | Event Date | Penalty | Abatement Due Date | Citation Type | Failure to Abate Inspection |
---|---|---|---|---|---|---|
Penalty | F: Formal Settlement | 01/09/2013 | $0.00 | 03/27/2012 | Serious | |
Penalty | C: Contested | 04/16/2012 | $5,000.00 | 03/27/2012 | Serious | |
Penalty | Z: Issued | 03/22/2012 | $5,000.00 | 03/27/2012 | Serious |
Text For Citation: 01 Item/Group: 006 Hazard:
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) On or about October 29, 2011, and at times prior, Continental Resources, Inc., as the controlling employer, did not ensure that Cyclone Drilling, Inc., a subcontractor, protected their employees from injury in that, the pony rods in the mud pumps area were inadequately guarded.